Arrester Dictionary
-
- Arrester
- Arrester 5kA Arrester
- Arrester 10kA Arrester
- Arrester Acceptance Tests
- Arrester Aging
- Arrester Body, EGLA SVU
- Arrester Classification
- Arrester Dead-Break
- Arrester Deadfront Type, Dead-Front Arrester
- Arrester Discharge Current
- Arrester Discharge Voltage
- Arrester Disconnector
- Arrester Distibution heavy Duty Class
- Arrester Distribution Light Duty Class
- Arrester Distribution Normal Duty Class
- Arrester Duty Cycle Rating
- Arrester EGLA
- Arrester GIS Arrester
- Arrester High Voltage
- Arrester Line Discharge Class
- Arrester Liquid Immersed Type
- Arrester Load-Break Arrester
- Arrester Medium Voltage
- Arrester MOV Type
- Arrester Polymer Housed
- Arrester Riser Pole
- Arrester Separable Type
- Arrester Station Class
- Arrester Unit
- Average Sparkover Voltage
-
- Back Fashover Rate (BFOR)
- Backflash
- Bending Moment
- BIL
- Breaking Load
- BSL
-
- Certification Tests
- CFO
- Classifying Current
- Coefficient of Grounding (COG)
- Composite Hollow Core Insulator
- Conditioning Tests
- Conformance Tests
- Continuous Current of an Arrester
- Continuous Operating Voltage of an Arrester, UC
- Conventional BIL
- Conventional BSL
- Conventional Withstand Voltage
- Coordination of Insulation
- Cracking
- Creepage Distance
- Crest Value
- Critical Flashover Voltage (CFO)
-
- Damage Limit
- Deadfront Type Arrester
- Deflector
- Degradation
- Design Tests
- Designation of an Impulse Shape
- Discharge Counter
- Discharge Current
- Discharge Indicator
- Discharge Voltage
- Discharge Voltage-Current Characteristic
- Discharge Withstand Current
- Disconnector
- Disruptive Discharge
- Distribution Arrester
- Duty-Cycle Voltage Rating
-
- Earth Fault Factor
- Electrical Aging
- Electrical Unit
- Electrical Unit SVU
- Energy Absorption Capability
- Externally Gapped Line Arresters, EGLA
-
- Fail-Open Current Rating For Liquid-Immersed Arrester
- Fail-Short Current Rating For Liquid-Immersed Arrester
- Fast-Front Overvoltage, FFO
- Fault Indicator
- Ferroresonance
- Flashover
- Flashover Rate, FOR
- Follow Current (i-follow)
- Follow Current of an Arrester
- Front of an Impulse
- Front-of-Wave Impulse Sparkover Voltage
-
- Gapless
- Grading or Control Ring
- Grading Current
- Ground Lead Disconnector (GLD)
- Ground Terminal
-
- High Current Impulse
- Highest Voltage for Equipment, Um
- Highest Voltage of a System, Us
- Housing
- Hydrophilic
- Hydrophobic
-
- IEC
- IEEE
- Impulse
- Impulse Protective Levels of an Arrester
- Impulse Protective Level
- Impulse Protective Volt-Time Characteristic
- Impulse Sparkover Voltage
- Impulse Sparkover Volt-Time Characteristic
- Impulse Withstand Voltage
- Indoor Arrester
- Insulation Coordination
- Insulation Level
- Internal Grading System of an Arrester
- Ionization Current
- Ionization Voltage
-
- Lead Length
- Lightning
- Lightning Current Impulse
- Lightning Impulse Protective Level, LIPL
- Lightning Impulse Withstand Voltage, LIWV
- Lightning Overvoltage
- Lightning Surge
- Line Arrester
- Line Discharge Class
- Line Terminal
- Liquid-Immersed Type Arrester
- Long-Duration Current Impulse
-
- Margin of Protection
- Maximum Continuous Operating Voltage Rating (MCOV)
- Maximum Design Cantilever Load-Static (MDCL-static)
- Maximum System Voltage
- Mean Breaking Load, MBL
- Mechanical Unit
- Metal-Oxide Surge Arrester(MOSA)
- Metal-Oxide Surge Arrester With External Series Gap (EGLA)
- Metal-Oxide Surge Arrester With Gapped Structures
- Metal-Oxide Surge Arrester Without Gaps
- Metal-Oxide Varistor (MOV)
- MOSA
- MOV Arrester
-
- Neutral Earthing or Grounding of a System
- Nominal Discharge Current of an Arrester, In
- Nominal Rate of Rise (of an Impulse)
- Nominal System Voltage
- Non Gapped Line Arresters, NGLA
- Non-Linear Metal-Oxide Resistor
- Nonself-Restoring Insulation
- Normal Lightning Current
-
Operating Duty Cycle
- Oscillatory Surge
- Outdoor Arrester
- Overvoltage
-
- Partial Discharge (PD)
- Peak Value
- Peak (Crest) Value of Opposite Polarity of an Impulse
- Polymer-Housed Arrester
- Porcelain-Housed Arrester
- Power-Frequency Sparkover Voltage
- Power-Frequency Withstand Voltage
- Power-Frequency Withstand Voltage Versus Time Characteristic of an Arrester
- Pressure-Relief Device of an Arrester
- Pressure Relief Rating
- Production Tests
- Prorated Section
- Prospective Short-Circuit Current
- Protective Characteristics of an Arrester
- Protective Zone
- Puncture
-
- Radio-Influence Voltage (RIV)
- Rated Frequency of an Arrester
- Rated Voltage of an Arrester Ur
- Rating
- Reference Current (Iref)
- Reference Current of an SVU (Iref)
- Reference Voltage (Vref) (Uref)
- Reference Voltage of an SVU (Uref)
- Residual Voltage of an Arrester, Ures
- Riser Pole Type Arrester
- Routine Tests
-
- Salt Deposit Density (SDD)
- Section of an Arrester
- Self-Restoring Insulation
- Separation Distance
- Series Gap
- Severe Lightning Current
- Shed
- Shielding Failure Flashover Rate, SFFOR
- Shielding Failure Rate, SFR
- Shunt Gap
- Single Energy Absorption Capability
- Slow-Front Overvoltage, SFO
- Sparkover
- SPD
- Specified Continuous Load (SCL)
- Specified Short-Term Load (SSL)
- Standard Lightning Impulse
- Standard Lightning Impulse Sparkover Voltage of an Arrester
- Standard Switching Impulses
- Statistical Basic Lightning Impulse Insulation Level (BIL)
- Statistical Basic Switching Impulse Insulation Level (BSL)
- Statistical Withstand Voltage
- Steep Current Impulse
- Strike Distance
- Surface Current of SVU
- Surge
- Surge Arrester
- Switching Current Impulse of an Arrester
- Switching Impulse Protective Level SIPL
- Switching Impulse Withstand Voltage, SIWV
- Switching Overvoltage
- Switching Surge
- Switching Surge Flashover Rate, SSFOR
- System Neutral Grounding or System Ground
- System Voltage
-
- Tail of an Impulse
- Temporary Overvoltage (TOV)
- Terminal Line Force
- Terminals
- Thermal Runaway of an Arrester
- Thermal Stability of an Arrester
- Time to Spark Over of an Arrester
- Torsional Loading
- TOV Curve
- Tracking
- Transient Overvoltage
- Transmission Line Arrester
- Traveling Wave
- Type Tests (design tests)
-
- Ultimate Mechanical Strength-Static (UMS-Static)
- Unit of an Arrester
- Unit Operation
-
- Valve Arrester
- Valve Element
- Vent
- Verification Test for Coordination Between Insulator and EGLA Withstand
- Very-Fast-Front Overvoltage, VFFO
- Vibration Withstand Test
- Virtual Total Duration of a Rectangular Impulse
- Virtual Duration of Wave Front
- Virtual Steepness of the Front of an Impulse
- Virtual Time to Half-Value on The Tail of an Impulse T2
- Virtual Zero Point (of an Impulse)
-
- Wave
- Wave Front (of an Impulse)
- Wave Tail (of an Impulse)
- Waveshape (of an Impulse Test Wave)
- Waveshape Designation (of an Impulse)
- Withstand Voltage